Category: Diamond Hydride FAQ
/
/
/
/
Analysis of Litchi seed extracts - AppNote
Read More
Aqueous Normal Phase ANP ballistic gradients compared to same in HILIC - Tips & Suggestions
Read More
Aqueous Normal Phase ANP solvent strength order - FAQ
Read More
Are Cogent 2.o HPLC columns compatible with Agilent 1290 Infinity II instruments - FAQ
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Biological extracts Diamond Hydride columns and LCMS ion source diminished peak height problem - FAQ
Read More
Blocked HPLC column from proteins from the sample matrix can be recovered - Tips & Suggestions
Read More
Can I use Acetone as a mobile phase solvent in Aqueous Normal Phase ANP - FAQ
Read More
Can I use ion pairing reagents with the Cogent Diamond Hydride HPLC column - FAQ
Read More
Can I use of the Cogent Diamond Hydride HPLC column above pH 7 in HPLC - FAQ
Read More
Can I use phosphoric acid or sodium phosphate with the Cogent Diamond Hydride HPLC column - FAQ
Read More
Can I use the Cogent Diamond Hydride column without mobile phase additives like formic acid - FAQ
Read More
Can I use triethylamine TEA with Cogent Diamond Hydride columns - FAQ
Read More
Can you measure EDTA plasma samples for creatine & creatinine - FAQ
Read More
Causes of high baseline noise with Cogent Diamond Hydride HPLC column - Tips & Suggestions
Read More
Cleaning Cogent TYPE-C silica based HPLC columns - Tips & Suggestions
Read More
Cogent silica hydride HPLC columns by order of hydrophobicity - Tips & Suggestions
Read More
Do Cogent TYPE-C Silica columns have a partial positive charge and if so is retention for basic compounds reduced because of this - Tech Information
Read More
Eliminate broad split peaks in Aqueous Normal Phase ANP methods and a methanol diluent- Tips & Suggestions
Read More
Fosetyl Aluminum analysis by HPLC - Tips & Suggestions
Read More
Fosetyl aluminum analysis by Reversed Phase HPLC - Tips & Suggestions
Read More
Glucose pyruvate taurocholic acid gamma glutamylcysteine and other analysis - Tips & Suggestions
Read More
High molecular weight compounds that won't retain on Cogent Diamond Hydride column try Cogent Bidentate C8 300 - Tips & Suggestions
Read More
High pressure develops after flushing a Cogent Diamond Hydride column with acetonitrile cause and solution - FAQ
Read More
How can I get separation of tartaric and malic acid in a complex mixture? - FAQ.
Read More
How can I restore my Diamond Hydride HPLC column after I ran out of mobile phase and air was accidently introduced into it - FAQ
Read More
How can I separate methacrylic acid and dodecyl benzene sulfonic acid - FAQ
Read More
How do I avoid distorted peak shapes when using a basic mobile phase pH for the analysis of a lipophilic amine - FAQ
Read More
How do retention and efficiency of asymmetric dimethylarginine ADMA compare using 4um vs 2.o Diamond Hydride columns - AppNote
Read More
How often do I need to do the conditioning procedure for a new Diamond Hydride column - FAQ
Read More
How to back flush and wash an HPLC column for reuse - Tips & Suggestions
Read More
How to get improved retention and peak shape for glutamine glutamic acid and aspartic acid - Tips & Suggestions
Read More
How to improve peak shapes, retention & carryover for polar compounds with the Cogent Diamond Hydride™ column - Tips & Suggestions
Read More
How to keep the Cogent Diamond Hydride column clean when using blood as a sample - Tips & Suggestions
Read More
I am not observing any peaks for succinic acid or alpha-ketoglutarate with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
I heard that there is not a good alternative to HILIC to achieve sufficient retention for some compounds - FAQ
Read More
Injection Technique for Aqueous Samples using Cogent TYPE-C Columns in ANP - Tips & Suggestions
Read More
Lower retention is observed when functional group in a compound is ionized - Tips & Suggestions
Read More
Method development tip for maleic hydrazide - Tips & Suggestions
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
Percentage of acid needed in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Polar and non polar peptides analyzed by LCMS with an Aqueous Normal Phase ANP method - Tips & Suggestions
Read More
Restoring the initial results with a method for analyzing AMP ADP ATP UDP and GPT in biological extracts - Tips & Suggestions
Read More
Retention and or peak shape for citric acid has changed compared to data from a previous HPLC run - Tips & Suggestions
Read More
Should I use methanol as the organic solvent in HPLC when using Aqueous Normal Phase ANP - FAQ
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Since Cogent TYPE-C Silica columns use a transition metal catalyst in production what is the presence of any trace quantity on the surface of the stationary phase- FAQ
Read More
Solving baseline problems in ANP methods with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Solving baseline problems in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Store and maintain Cogent Diamond Hydride HPLC columns - How To
Read More
Suggestions for HPLC method development with silica hydride columns - Tips & Suggestions
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Tizanidine HCl HPLC Method transferred to near UHPLC - AppNote
Read More
Use a low concentration of salt in your mobile phase to avoid ion suppression and build up on your inlet source - Tips & Suggestions
Read More
Using an Aqueous Normal Phase ANP method will sodium ions interfere with succinate when analyzing sodium succinate - FAQ
Read More
Using inorganic buffers for HPLC UV analysis of citric acid - Tips & Suggestions
Read More
Using two HPLC columns together in a tandem separation for polar and non polar retention - Tips & Suggestions
Read More
What are some notable examples of journal articles that feature Aqueous Normal Phase ANP methods in metabolomics studies - FAQ
Read More
What is the carbon load of the Cogent Diamond Hydride HPLC column - FAQ
Read More
What is the compatibility of Cogent TYPE-C Silica HPLC columns with UHPLC instruments - FAQ
Read More
What is the maximum salt concentration to use with Cogent TYPE-C HPLC columns with HPLC or LCMS - FAQ
Read More
What is the maximum temperature for Cogent Diamond Hydride HPLC columns - FAQ
Read More
What is the recommended pH range for Cogent Diamond Hydride HPLC columns - FAQ
Read More
What pressure should I expect with a Diamond Hydride 2.o HPLC column at flow rates from 0.2 to 2.0mL / min - FAQ
Read More
Which Cogent TYPE-C column do you recommend for the separation of positional isomers by HPLC or LCMS - FAQ
Read More
Which column do you suggest for Cocaine & metabolite Ecognin separation - Tips & Suggestions
Read More
Why am I observing broad split peaks in Aqueous Normal Phase ANP when using acetonitrile and methanol diluents - FAQ
Read More
Why am I seeing two peaks for quaternium15 Dowicil-75 in LCMS - FAQ
Read More
Why am I seeing two peaks for quaternium-15 or Dowicil-75 in my LCMS data - FAQ
Read More
Why do I have lower than normal back pressure with Cogent Diamond Hydride HPLC columns - FAQ
Read More
Why doesn't triphenylamine a tertiary amine retain in Aqueous Normal Phase ANP - FAQ
Read More
Working with ammonium acetate and LCMS requires attention to cleaning - Tips & Suggestions
Read More